Hisense Reduced Dehumidification Capacity

Dehumidifier runs but collects very little water compared to before.

Advertisements

Possible Causes

Partially clogged condenser coil, Partially restricted capillary tube, Weak compressor, Dirty air filter reducing airflow

How to Fix / Troubleshooting

Safety first: Unplug the unit before cleaning.

  • Clean air filter: Remove and wash the filter with mild soap and water. Let it dry completely before reinstalling.
  • Clean coils: Access the evaporator and condenser coils and gently brush or vacuum off dust and lint. Avoid bending the fins.
  • Check room size and conditions: Ensure the dehumidifier capacity matches the room size and humidity level. Oversized spaces may overwhelm a small unit.
  • Inspect for icing: If the evaporator ices up quickly, airflow or refrigerant issues may be present. Defrost the unit and improve airflow.
  • Service if needed: If performance remains poor after cleaning and proper sizing, a weak compressor or partial restriction may be the cause; contact a technician.
Advertisements

Repair Difficulty

Easy 2/5
Advertisements