Hisense No Power / Dead Unit

Dehumidifier will not power on at all; display is blank and no lights.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal fuse on main PCB, Failed power supply section of control board, Faulty power cord, Tripped GFCI outlet or breaker

How to Fix / Troubleshooting

Safety first: Ensure the outlet is not live before touching plug prongs. Unplug the unit before opening any panels.

  • Check outlet: Plug a lamp or other device into the same outlet to verify power. Reset any tripped breaker or GFCI.
  • Inspect power cord: Look for cuts, burns, or kinks. If damaged, replace the cord set.
  • Try another outlet: Move the unit to a known-good outlet on a different circuit.
  • Internal fuse: If comfortable, remove the control panel and locate the small fuse on the main PCB. If blown, replace with the same type and rating. If it blows again immediately, a deeper fault exists.
  • Board replacement: If the fuse is good but there is still no power, the main control board's power supply is likely failed and should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board (PCB)
Check Price on Amazon

We may earn a commission from links on this page.