F2
Hisense
Ambient Temperature Sensor Short Circuit
Dehumidifier shows F2 and stops; may show unrealistic temperature readings.
Advertisements
Possible Causes
Shorted NTC sensor, Moisture bridging sensor leads, Pinched sensor cable, Shorted connector at PCB
How to Fix / Troubleshooting
Safety first: Unplug the unit.
- Dry the sensor area: If the unit has been exposed to condensation or a spill, allow it to dry completely. Use a fan to speed drying.
- Inspect sensor wiring: Look for pinched or crushed sensor wires that could be shorting together.
- Check connector: Remove and inspect the sensor connector on the PCB for corrosion or conductive debris. Clean with isopropyl alcohol if needed.
- Replace sensor: If the sensor measures near 0 Ω or shows visible damage, replace it.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Ambient Temperature Sensor (NTC)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements