F2
Hisense Ambient Temperature Sensor Short Circuit

Dehumidifier shows F2 and stops; may show unrealistic temperature readings.

Advertisements

Possible Causes

Shorted NTC sensor, Moisture bridging sensor leads, Pinched sensor cable, Shorted connector at PCB

How to Fix / Troubleshooting

Safety first: Unplug the unit.

  • Dry the sensor area: If the unit has been exposed to condensation or a spill, allow it to dry completely. Use a fan to speed drying.
  • Inspect sensor wiring: Look for pinched or crushed sensor wires that could be shorting together.
  • Check connector: Remove and inspect the sensor connector on the PCB for corrosion or conductive debris. Clean with isopropyl alcohol if needed.
  • Replace sensor: If the sensor measures near 0 Ω or shows visible damage, replace it.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ambient Temperature Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.