F4
Hisense
Evaporator Temperature Sensor Short Circuit
Dehumidifier displays F4 and stops; may indicate incorrect coil temperature readings.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted NTC sensor, Moisture causing short, Pinched sensor cable, Shorted connector at PCB
How to Fix / Troubleshooting
Safety first: Disconnect power.
- Inspect sensor and wiring: Look for crushed or pinched wires near the evaporator coil or cabinet edges.
- Dry moisture: If the sensor area is wet, dry thoroughly and allow time for moisture to evaporate.
- Check connector: Clean any corrosion or debris from the sensor connector on the PCB.
- Replace sensor: If the sensor measures near 0 Ω or shows visible damage, replace it.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Evaporator Temperature Sensor (NTC)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements