F0
Homedics Refrigerant System / Low Temperature Protection Fault

Homedics dehumidifier shows F0 and stops dehumidifying.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Evaporator coil icing, Room temperature too low for operation, Faulty coil temperature sensor, Low refrigerant charge or restriction

How to Fix / Troubleshooting

Safety: Unplug the unit before inspection. Do not attempt sealed system repairs yourself.

Steps to address F0:

  • Check room temperature: Ensure the room is within the operating range (typically above 41–50°F / 5–10°C). Move the unit to a warmer area if needed.
  • Inspect for ice: Remove the front panel and look at the evaporator coil. If it is iced over, turn the unit off and allow it to defrost completely.
  • Improve airflow: Clean the air filter and intake grille. Ensure at least 12 inches clearance around the unit.
  • Sensor check: If F0 recurs without icing, the coil temperature sensor may be faulty. Replace the Homedics evaporator temperature sensor if necessary.
  • Professional service: Persistent F0 with icing or poor performance may indicate a refrigerant issue. Contact a qualified technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Evaporator Temperature Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements