Homedics
No Dehumidification / Refrigeration Failure
Homedics dehumidifier runs but does not collect water; humidity in room remains high.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Low or lost refrigerant charge, Failed compressor, Severely iced evaporator coil, Blocked airflow across coils
How to Fix / Troubleshooting
Safety: Unplug before removing covers. Do not attempt to open the sealed refrigeration system.
Diagnostic steps:
- Check room conditions: Ensure the room is warm enough (above ~65°F / 18°C) for effective dehumidification.
- Inspect coils: Remove the cover and check if the evaporator coil is icing over. If so, clean the air filter and grilles and allow the unit to defrost.
- Compressor operation: Listen for the compressor running (a low hum) after the fan starts. If the compressor never starts, see compressor-related faults.
- Professional service: If the compressor runs but the coil does not get cold or no water is collected after several hours, the sealed system may be low on refrigerant or restricted. This requires a qualified refrigeration technician; in many compact units, replacement is more cost-effective.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Compressor and Sealed Refrigeration System
Check Price on Amazon