Honeywell
Fan Motor Failure
Dehumidifier fan does not run, but compressor attempts to start; unit overheats or shuts down.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Burned out fan motor, Seized fan bearings, Broken fan blade or blower wheel, Faulty fan relay on control board
How to Fix / Troubleshooting
Safety: Unplug the unit. Do not operate the compressor without a functioning fan; this can cause overheating.
Steps:
- Spin test: With power off, try spinning the fan blade by hand. If it is stiff or does not spin freely, the motor or bearings are failed.
- Inspect fan blade: Check for broken or obstructed blades; replace if damaged.
- Voltage test: If you are qualified, apply power and test for voltage at the fan motor leads when the unit is calling for fan operation. If voltage is present but the motor does not run, replace the fan motor.
- Control board: If no voltage is present at the motor and wiring is intact, the fan relay or control board may be defective and require replacement.
Note: Always replace the fan motor with a Honeywell‑specified part to ensure correct airflow and noise levels.