Dehumidifier indicates bucket full even when the bucket is empty and correctly installed.
Advertisements
Possible Causes
Stuck bucket float in raised position, Misaligned bucket engaging the switch incorrectly, Faulty bucket full switch, Broken float arm
How to Fix / Troubleshooting
Safety: Unplug before inspecting the float and switch.
Steps:
- Remove bucket: Take out the bucket and inspect the float mechanism. Ensure it moves freely and is not obstructed by dirt or scale.
- Clean float assembly: Rinse the float and bucket with warm water to remove mineral deposits.
- Check switch operation: Locate the bucket full switch in the cabinet and manually actuate it. If the unit responds correctly when pressed, adjust the bucket so it engages properly.
- Replace switch or float: If the switch does not change state when actuated, replace the bucket full switch. If the float is broken or waterlogged, replace the float assembly or bucket.
Tip: Mark the correct bucket seating position so it is reinstalled consistently after emptying.