Honeywell Short Cycling

Dehumidifier shuts off after a few minutes and restarts frequently; does not maintain continuous operation.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Humidity setpoint too close to room humidity, Faulty humidity sensor, Overheating compressor triggering overload, Restricted airflow

How to Fix / Troubleshooting

Safety: Unplug before internal inspection.

Steps:

  • Adjust setpoint: Set the desired humidity at least 10–15% below current room humidity.
  • Clean filter and grilles: Ensure unrestricted airflow to prevent overheating.
  • Check ambient temperature: Avoid operating in very hot rooms where the compressor may overheat.
  • Test humidity sensor: If the unit cycles off while the room is still very humid, test and replace the humidity sensor if it reads incorrectly.

Note: Persistent short cycling with a hot compressor may indicate a failing compressor or overload protector, which often justifies unit replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Humidity Sensor Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements