LO
Honeywell
Low Ambient Temperature Lockout
Dehumidifier display shows "LO" and the unit does not run or runs intermittently.
Advertisements
Possible Causes
Room temperature below operating range, Faulty ambient temperature sensor reading too low, Unit placed near cold window or draft, Control board misreading sensor
How to Fix / Troubleshooting
Safety: No internal work is required for basic checks; unplug before opening the cabinet.
Steps:
- Check room temperature: Verify the room is above the minimum operating temperature (typically 41°F / 5°C). Move the unit to a warmer area if needed.
- Avoid cold drafts: Do not place the dehumidifier directly on a cold concrete floor or next to a cold window where the sensor can be fooled by localized cold air.
- Power reset: Unplug for 5 minutes and restart. If LO persists in a warm room, the ambient sensor may be faulty.
- Inspect and test sensor: Access the ambient temperature sensor near the air intake, check wiring, and test resistance. Replace if readings are out of spec.
Note: LO is often a normal protection indication in cold basements; the unit will resume operation automatically when the room warms up.