Insignia
Improper Control Cycling / Sensor Placement Issue
Dehumidifier short cycles; turns on and off every few minutes
Advertisements
Possible Causes
Humidity sensor too close to discharge air, Unit oversized for room size, Faulty humidity sensor giving unstable readings, Control board hysteresis too narrow
How to Fix / Troubleshooting
Steps:
- Relocate unit: Move the dehumidifier away from corners and direct airflow back into the intake. Place it more centrally in the room.
- Check room size: Ensure the dehumidifier capacity matches the room size. An oversized unit can reach setpoint too quickly and cycle often.
- Sensor inspection: Access the humidity sensor and ensure it is positioned to sample room air, not directly in the warm discharge stream. Reposition if necessary.
- Sensor replacement: If humidity readings on the display fluctuate wildly, replace the humidity sensor module.
Note: Some cycling is normal, but very rapid on/off can reduce compressor life.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Humidity Sensor Module
Check Price on Amazon
We may earn a commission from links on this page.