Insignia
No Power / Dead Unit
Dehumidifier will not power on at all; display is blank
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blown internal fuse on main control board, Faulty power cord, Failed main control board, Tripped household circuit breaker
How to Fix / Troubleshooting
Safety: Unplug the unit before opening. If you smell burning or see smoke, do not attempt repair; contact a professional.
Steps:
- Outlet check: Plug a lamp or other device into the same outlet to confirm power. Reset the household breaker or GFCI if tripped.
- Inspect power cord: Look for cuts, kinks, or burn marks. If damaged, replace the cord set or have it replaced by a technician.
- Access control board: Remove the rear or side panel to expose the main PCB. Look for an onboard fuse (glass or blade type).
- Test/replace fuse: With the unit unplugged, test the fuse for continuity. If blown, replace with the same rating. If it blows again immediately, there is a deeper electrical fault.
- Board inspection: Check for burnt components or cracked solder joints. If present, replace the main control board with an Insignia-compatible part.
Warning: Do not bypass or oversize the fuse; this is a fire hazard.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.