Inventor Compressor Start Failure

Dehumidifier powers on but compressor never starts; only fan runs

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor start relay, Faulty compressor capacitor, Open compressor winding, Main PCB not sending start signal

How to Fix / Troubleshooting

Safety: Unplug the unit. The compressor terminals carry mains voltage; only proceed if you are comfortable and experienced with electrical testing.

  • Listen for clicks: When the unit calls for dehumidification, you should hear a click from the relay and a hum from the compressor. No sound may indicate a control or relay issue.
  • Access compressor terminals: Remove the rear panel and compressor cover. Inspect the start relay and run capacitor for burn marks or bulging.
  • Test capacitor: Use a capacitance meter to verify the capacitor value matches the rating. Replace if out of tolerance.
  • Check relay: If the relay is a plug-on type, replace it with the correct Inventor compressor start relay.
  • Winding test (advanced): With power disconnected, measure resistance between compressor terminals. Open or shorted windings indicate a failed compressor, which requires professional replacement.
  • PCB control: If all compressor components test good, the main PCB may not be energizing the relay and should be replaced.