Inventor No Dehumidification / Poor Cooling Performance

Dehumidifier runs but does not collect water; humidity does not decrease

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge or leak, Severely dirty evaporator or condenser coil, Faulty compressor, Blocked capillary tube or expansion device

How to Fix / Troubleshooting

Safety: Unplug the unit before cleaning. Do not attempt to open the sealed refrigeration system.

  • Check humidity setting: Ensure the target humidity is set lower than the current room humidity.
  • Clean filter and coils: Remove and wash the air filter. Access both coils and gently clean dust and lint with a soft brush and vacuum.
  • Observe evaporator: After running for 15–20 minutes, the evaporator should be uniformly cool with some condensation. If only a small section is cold or there is no cooling, a sealed system issue is likely.
  • Room conditions: Verify the room is closed (doors/windows) and not too cold; low temperatures reduce water collection.
  • Professional service: If cleaning and proper setup do not restore performance, contact a refrigeration technician to check refrigerant charge and compressor health.
Advertisements

Repair Difficulty

Hard 4/5
Advertisements