E6
Inventor Communication Error Between Display Board and Main PCB

Dehumidifier shows E6 and will not run the compressor

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose communication cable between display PCB and main PCB, Damaged ribbon cable, Oxidized connectors, Failed display PCB or main control PCB

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing control boards.

  • Access control panel: Remove the top or front cover to expose the display/control PCB. Follow the flat ribbon or multi-wire harness that connects to the main PCB.
  • Reseat connectors: Disconnect the cable at both ends, inspect for bent pins or corrosion, then firmly reconnect. Ensure the cable is not pinched by the cabinet.
  • Inspect cable: Look for visible cuts, kinks, or broken conductors. Replace the display-to-main PCB harness if damaged.
  • Check for moisture: Any signs of water ingress around the control panel can cause communication faults. Dry the area thoroughly and correct the source of moisture (e.g., leaking top cover).
  • Board replacement: If reseating and replacing the cable does not clear E6, either the display PCB or main PCB is defective. Replace the display PCB first (usually cheaper), then the main control PCB if needed. Board-level repair is best left to a technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Display-to-Main PCB Harness
Check Price on Amazon

We may earn a commission from links on this page.