F0
Inventor General Sensor Fault / Sensor Circuit Abnormal

Dehumidifier displays F0 and does not start normal operation

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Any NTC sensor open or shorted, Sensor harness unplugged, Corroded sensor connectors, Main PCB sensor input failure

How to Fix / Troubleshooting

Safety: Unplug the unit before inspection.

  • Identify sensors: Most Inventor dehumidifiers have at least an ambient NTC, evaporator NTC, and sometimes a discharge or defrost NTC. Locate each sensor and its wiring.
  • Check all connectors: One by one, unplug and replug each sensor connector on the main PCB. Look for bent pins or corrosion.
  • Visual inspection of wires: Ensure no sensor wires are cut, pinched by panels, or chewed by pests.
  • Resistance test: Measure resistance of each sensor at room temperature and compare values. Any sensor reading 0 Ω or infinite is defective.
  • Replace faulty sensor(s): Install the correct Inventor NTC sensor for the location that tests bad.
  • PCB replacement: If all sensors test good and F0 persists, the main PCB sensor circuit may be damaged and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

NTC Sensor (location-specific)
Check Price on Amazon