F1
Inventor
Humidity Sensor Calibration / Range Error
Dehumidifier shows F1 and may still run in a limited mode
Advertisements
Possible Causes
Humidity sensor out of calibration, Sensor contaminated by chemicals or smoke, Faulty humidity sensor module, Main PCB ADC error
How to Fix / Troubleshooting
Safety: Disconnect power before accessing the control panel.
- Reset settings: Restore the dehumidifier to factory settings (refer to user manual) and power cycle the unit.
- Clean intake area: If the unit has been used in a dusty or smoky environment, gently clean the air intake and area around the humidity sensor with a soft brush.
- Compare with external hygrometer: Place an independent hygrometer near the unit. If readings differ drastically, the internal sensor is likely faulty.
- Replace humidity sensor: Install a new Inventor humidity sensor module and reconnect it to the PCB.
- PCB issue: If a new sensor does not correct F1, the main PCB’s analog-to-digital converter may be defective and the board should be replaced.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Humidity Sensor Module
Check Price on Amazon