E7
Keystone
Internal EEPROM / Memory Error on Control Board
Dehumidifier shows E7 and will not start or shuts down shortly after starting.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Corrupted firmware or EEPROM on main control board, power surge damage, defective main PCB
How to Fix / Troubleshooting
Safety: Always unplug the unit before removing covers or touching internal components.
Steps:
- Power cycle: Unplug the unit for 10–15 minutes to allow capacitors to discharge, then plug back in. Sometimes this clears transient memory faults.
- Check power quality: Plug the unit directly into a properly grounded wall outlet (no extension cords or power strips). Voltage drops or surges can trigger memory errors.
- Surge protection: If E7 occurred after a storm or outage, consider using a surge protector in the future, but test the unit first directly on a known-good outlet.
- Board replacement: If E7 persists, the main control board is likely damaged. Replacement of the board is the only practical repair and is best performed by a qualified technician.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements