F2
Keystone
Temperature Sensor Error (Ambient or Coil)
Humidifier or dehumidifier shows F2 and stops or runs only briefly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted temperature sensor, sensor knocked out of position, damaged harness, failed control board sensor circuit
How to Fix / Troubleshooting
Safety: Unplug before opening the cabinet.
Steps:
- Identify which sensor: Consult the model's tech sheet if available; F2 may refer to ambient or coil sensor depending on model.
- Locate the sensor: Ambient sensors are near the air intake; coil sensors are clipped to the evaporator.
- Inspect and reseat: Check for loose mounting, damaged wires, or corroded connectors. Reseat the connector on the PCB.
- Replace sensor: If the sensor is visibly damaged or tests open/short with a multimeter, replace it with the correct Keystone temperature sensor for your model.
- Board diagnosis: If a new sensor does not resolve F2, the main control board may need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Temperature Sensor (Thermistor)
Check Price on Amazon
We may earn a commission from links on this page.