LO
Keystone Low Ambient Temperature Protection

Dehumidifier display shows LO and unit may not start or may run only the fan.

Advertisements

Possible Causes

Room temperature below operating range, faulty ambient temperature sensor reading too low, control board miscalibration

How to Fix / Troubleshooting

Note: LO is usually an informational code indicating the room is too cold for normal dehumidification.

  • Check room temperature: Use a separate thermometer to verify the room is above the minimum operating temperature (typically around 41°F/5°C). If not, move the unit to a warmer space.
  • Allow warm-up: If the unit was stored in a cold area, let it sit unplugged at room temperature for several hours before use.
  • Sensor check: If LO appears even in a warm room, inspect the room temperature sensor and its wiring for damage or disconnection.
  • Replace sensor: Install a new ambient temperature sensor if the old one is faulty. If LO persists, the main control board may be misreading and require replacement.