P1
Keystone
Defrost Mode Active (Automatic Coil Defrost)
Dehumidifier displays P1 and stops dehumidifying; fan may continue to run.
Advertisements
Possible Causes
Low room temperature causing coil icing, restricted airflow across evaporator, sensor detecting frost buildup, normal automatic defrost cycle
How to Fix / Troubleshooting
Note: P1 on many Keystone dehumidifiers is not a fault but an indication that the unit is in defrost mode.
- Allow defrost cycle: Leave the unit plugged in and powered on. The compressor will stop while the fan runs to melt ice from the evaporator coil. P1 should clear automatically within 10–30 minutes.
- Check room temperature: If the room is below about 41–50°F (5–10°C), move the unit to a warmer area. Operating in very cold spaces will cause frequent defrost cycles.
- Clean filter and grilles: A dirty filter or blocked intake/exhaust reduces airflow and promotes icing. Remove and wash the filter; vacuum dust from the grilles.
- Persistent P1: If P1 never clears and the coil is heavily iced, unplug the unit and allow it to thaw completely. If icing recurs quickly in a warm room with clean filters, the evaporator temperature sensor or control board may be misreading and should be inspected.
Advertisements
Repair Difficulty
Very Easy