E9
Klarstein
Compressor Current / Overload Detection Error
Dehumidifier shows E9 and will not start compressor; fan may run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted compressor windings, Failed compressor start relay or PTC, Faulty current-sensing circuit on main PCB, Short circuit in compressor wiring harness
How to Fix / Troubleshooting
High-voltage safety: Unplug the unit. Compressor and mains circuits can be lethal. If you are not experienced with electrical measurements, contact a professional.
- Visual inspection: Remove the rear cover to access the compressor compartment. Look for burnt wires, melted connectors, or a burnt smell near the compressor or PCB.
- Check compressor wiring: Ensure all spade connectors on the compressor terminals and overload protector are tight and not discolored.
- Test compressor (advanced): With the unit unplugged, disconnect the compressor terminals and measure resistance between each pair. Very low resistance (near 0 Ω) or continuity to ground indicates a shorted compressor, which requires professional replacement.
- Inspect start device: Many Klarstein units use a PTC start relay or electronic module. If cracked, burnt, or rattling when shaken, replace the compressor start device with the correct part.
- PCB fault: If compressor and wiring test normal but E9 persists, the main PCB’s current-sensing or relay circuit may be defective and should be replaced.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Compressor Start Relay / PTC
Check Price on Amazon