Levoit Water Level Detection Error

Humidifier tank shows full, but the unit indicates low water and will not run.

Advertisements

Possible Causes

Stuck float in low position, Misaligned tank not depressing valve, Dirty or scaled float chamber, Faulty reed switch or level sensor

How to Fix / Troubleshooting

Safety: Unplug the unit and remove the tank.

Steps:

  • Check tank valve: Press the valve on the bottom of the tank to ensure it opens smoothly. Replace the valve seal if stuck.
  • Inspect float: Locate the float in the base and verify it moves freely. Clean any mineral deposits with vinegar and water.
  • Align tank: Reinstall the tank carefully, ensuring it is fully seated and not tilted.
  • Test: Plug in and power on. If the low water indication remains, the reed switch or electronic level sensor may be faulty and should be replaced.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Level Float Switch Assembly
Check Price on Amazon