Levoit No Power / Dead Unit

Humidifier will not power on at all (no lights, no display).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective power adapter or power cord, Blown internal fuse on main PCB, Failed power supply section on PCB, Broken power button or control panel

How to Fix / Troubleshooting

Safety: Unplug before opening the unit. If you are not comfortable working around mains voltage, contact a technician.

Steps:

  • Verify outlet: Test the outlet with another device.
  • Check adapter: For models with external adapters, test the adapter output with a multimeter. Replace if there is no or low output.
  • Inspect power cord: For corded models, check for cuts, kinks, or burn marks. Replace the cord set if damaged.
  • Open base and check fuse: Many Levoit units have a small fuse on the PCB near the power input. If visibly blown or open (no continuity), replace with the same type and rating.
  • Check for board damage: If the fuse blows again immediately or the board shows burn marks, the power supply section is damaged. Replace the main PCB.
  • Control panel: If the board has power but the panel is dark, the display/control board may be faulty and should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Power Adapter
Check Price on Amazon