F3
Meaco Ultrasonic Transducer / Nebulizer Fault

Meaco humidifier shows F3 and no mist is produced

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ultrasonic transducer disc, Mineral scale buildup on transducer, Loose transducer wiring, Driver circuit failure on PCB

How to Fix / Troubleshooting

Safety: Unplug the humidifier and empty the water tank before working on the base.

Steps:

  • Clean the transducer: Locate the round metal ultrasonic transducer in the base. Gently clean mineral deposits with a cotton swab and a 1:1 vinegar-water solution. Do not scratch the surface.
  • Rinse and dry: Wipe with clean water and dry thoroughly before refilling the tank.
  • Check wiring: Inspect the wires from the transducer to the PCB for damage or loose connections. Reseat connectors if present.
  • Test operation: Reassemble, refill, and test. If F3 persists and there is still no mist, the transducer or driver circuit is likely faulty.
  • Replace transducer: Install a new Meaco ultrasonic transducer assembly following the model-specific procedure.
  • PCB replacement: If a new transducer does not fix F3, the ultrasonic driver circuit on the main PCB may be defective and require replacement.