F4
Meaco Overheat / Dry‑Run Protection Fault

Meaco humidifier displays F4 and shuts down

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Unit operated without water, Blocked air outlet, Failed overheat sensor or thermal fuse, Main PCB misreading temperature

How to Fix / Troubleshooting

Safety: Unplug the humidifier and allow it to cool for at least 30 minutes.

Steps:

  • Check water level: Ensure the tank is filled to the correct level and properly seated.
  • Clear vents: Inspect the air outlet and intake for blockages. Remove dust or obstructions.
  • Reset: After cooling and refilling, reconnect power and test. If F4 returns quickly, internal overheat protection may be tripping.
  • Inspect overheat sensor: Open the housing and locate the overheat thermostat/thermal fuse near the heater or main board (on warm‑mist models). Check for signs of damage or discoloration.
  • Replace sensor: If the thermal fuse is open or thermostat is faulty, replace with the correct Meaco-rated part.
  • PCB fault: Persistent F4 with good sensors may indicate a main control PCB issue requiring professional service.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Overheat Thermostat / Thermal Fuse
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements