Medisana Improper Defrost or Low Airflow

Dehumidifier freezes up; evaporator coil becomes a solid block of ice.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defrost sensor misreading temperature, Fan not running at full speed, Very low room temperature, Blocked air filter or coil fins

How to Fix / Troubleshooting

Safety: Unplug the unit and allow all ice to melt before servicing.

  • Room temperature: Ensure the room is within the recommended operating range. Move to a warmer room if necessary.
  • Clean filter and coils: Wash the filter and vacuum the evaporator fins to restore airflow.
  • Check fan operation: Confirm the fan runs at normal speed. Replace the fan motor if weak.
  • Defrost sensor: Inspect and, if necessary, replace the defrost NTC sensor attached to the evaporator.
  • Test after thawing: Once fully thawed and cleaned, restart and monitor for re-freezing. Persistent issues may require PCB replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Defrost NTC Sensor
Check Price on Amazon