E4
Medisana Defrost / Coil Temperature Sensor Fault

Dehumidifier displays E4 and will not run; sometimes appears after long operation or defrost cycle.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective defrost NTC sensor, Sensor dislodged from evaporator coil, Broken sensor harness, Control board sensor circuit failure

How to Fix / Troubleshooting

Safety: Disconnect from mains before opening the cabinet.

  • Locate defrost sensor: On Medisana dehumidifiers, the defrost sensor is often clipped to the lower part of the evaporator coil or attached to the refrigerant tubing.
  • Check attachment: Make sure the sensor is in firm contact with the coil/tube. If it has fallen off, reattach using the original clip or aluminum tape rated for refrigeration use.
  • Inspect cable and plug: Follow the cable back to the PCB. Ensure the connector is fully seated and there are no visible breaks.
  • Replace sensor if needed: If the sensor is physically damaged or tests open/short with a multimeter, replace it with the correct Medisana defrost NTC sensor.
  • Board diagnosis: If a known-good sensor does not clear E4, the main control PCB is likely defective and should be replaced by a qualified technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Defrost NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.