E6
Medisana Compressor Current / Overload Detection Error

Dehumidifier displays E6 and stops; fan may run but compressor does not.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty current sensing circuit on main PCB, Shorted compressor winding, Loose compressor wiring connector, Defective main control PCB

How to Fix / Troubleshooting

Safety: Unplug the dehumidifier. High voltage and stored charge may be present on capacitors.

  • Check wiring: Remove the cover and inspect the wiring to the compressor. Ensure all spade connectors are tight and not burnt.
  • Look for obvious damage: Burn marks on the PCB near the compressor relay or current sensor (shunt resistor or current transformer) indicate board failure. In this case, replace the main control PCB.
  • Compressor test (advanced): With the unit unplugged, measure resistance between compressor terminals if accessible. If any winding is shorted to ground or readings are far from the service manual values, the compressor is defective and requires professional replacement.
  • Board replacement: If wiring and compressor test normal, replace the main control PCB with a Medisana-compatible board. This is typically a level-4–5 repair and may be best left to a technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control PCB
Check Price on Amazon