Ambient Temperature Out of Range / Sensor Calibration Error
Dehumidifier shows E7; unit may beep and refuse to start.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Ambient NTC sensor reading out of range, Sensor not positioned correctly in airflow, Firmware calibration error, Defective ambient temperature sensor
How to Fix / Troubleshooting
Safety: Disconnect power before opening the housing.
- Check room temperature: Verify the room is within the operating range specified by Medisana (often around 5–35 °C). Move the unit to a suitable environment and try again.
- Inspect ambient sensor: Locate the ambient NTC sensor near the air intake grille. Ensure it is not touching hot components and is exposed to room air.
- Check wiring and connector: Make sure the sensor harness is intact and firmly connected to the PCB.
- Replace sensor: If the sensor is damaged or tests open/short, replace it with the correct ambient NTC sensor for your model.
- Persistent E7: If the sensor is good and E7 remains, the control board firmware or sensor circuit is likely faulty. Replace the main control PCB.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ambient NTC Temperature Sensor