Medisana Partial PCB Failure Affecting Ultrasonic Circuit Only

Humidifier night-light or LED illumination works, but mist function does not start.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ultrasonic driver IC, Blown transducer fuse or resistor, Loose connector to transducer, User mode set to light-only (if supported)

How to Fix / Troubleshooting

Safety: Unplug before opening the base.

  • Check mode settings: Ensure the unit is not in a decorative light-only mode. Select a mist mode on the control panel.
  • Inspect wiring: Open the base and check the connector from the PCB to the ultrasonic transducer. Reseat it firmly.
  • Visual PCB check: Look for burnt components near the transducer driver area. If found, the PCB should be replaced.
  • Replace transducer or PCB: If wiring is intact and there is still no mist, replace the ultrasonic transducer module. If that fails, replace the main control PCB.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ultrasonic Transducer Module