Medisana Reduced Ultrasonic Output Due to Scaling or Low Voltage

Humidifier produces very weak mist output even at maximum setting.

Advertisements

Possible Causes

Mineral scale buildup on transducer, Low water level not fully covering transducer, Failing power supply to ultrasonic driver, Partially blocked mist outlet or fan

How to Fix / Troubleshooting

Safety: Unplug the unit before cleaning.

  • Use demineralized water: Switch to distilled or demineralized water to prevent further scale buildup.
  • Descale transducer and basin: Fill the basin with a vinegar-water mix (1:1) to cover the transducer. Let sit 20–30 minutes, then gently wipe away loosened deposits.
  • Clean mist outlet: Remove the top cover and clean the mist outlet channel and any directional nozzles with a soft brush.
  • Check fan: Ensure the internal fan is running and the air path is not blocked by dust. Clean the fan grille.
  • Power supply check: If mist remains weak, the internal power supply or driver circuit may be failing. Replacement of the main PCB or power board may be required.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ultrasonic Transducer Module
Check Price on Amazon