E1
Midea
Room Temperature Sensor (NTC) Failure or Open Circuit
Dehumidifier will not run; display shows E1 shortly after power-on.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective ambient temperature NTC sensor, Broken or loose sensor harness, Corroded connector on main control board, Failed main PCB temperature input circuit
How to Fix / Troubleshooting
Safety first: Unplug the dehumidifier before removing any panels. Capacitors on the control board can hold a charge; avoid touching board components directly.
- Power reset: Unplug the unit for 5 minutes, then plug back in and try again. If E1 returns, continue.
- Access the control area: Remove the front or top cover (varies by Midea model) by taking out visible screws and gently releasing plastic clips.
- Locate the ambient temperature sensor: On most Midea dehumidifiers, the room temperature NTC is clipped near the air intake grille or on the evaporator inlet area, with two thin wires going to the main PCB.
- Check wiring and connector: Ensure the sensor plug is fully seated on the main PCB. Look for broken wires, pinched cable, or corrosion. Reseat the connector several times.
- Test the sensor (if you have a multimeter): Disconnect the NTC from the board and measure resistance. At ~25°C (77°F), many Midea NTCs read around 10kΩ (check service manual if available). If it reads open (OL) or near 0Ω, the sensor is bad.
- Replace the sensor if faulty: Order a compatible "Midea ambient temperature sensor" or "Midea NTC sensor" for your model. Clip the new sensor in the same location and route wires as original, then reconnect to the PCB.
- If sensor tests good: The temperature input circuit on the main PCB may be defective. Inspect the board for burn marks or corrosion. If present, replace the main control board.