E5
Midea Compressor Overload or Current Protection Error

Dehumidifier shows E5 and will not start compressor; fan may still operate.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Locked or seized compressor, Failed compressor start device (PTC relay/overload), Low line voltage or wiring issue, Faulty main control board compressor drive circuit

How to Fix / Troubleshooting

Safety: Unplug the unit. The compressor and start components can get very hot; allow the unit to cool for at least 15 minutes before touching.

  • Check power supply: Plug the dehumidifier directly into a wall outlet (no extension cords). Verify outlet voltage is within 110–125V (for North American models) using a multimeter if available.
  • Listen for compressor attempt: When powered, you should hear a click and a low hum as the compressor tries to start. A loud click followed by silence may indicate a bad start device.
  • Access compressor compartment: Remove rear or side panel to expose the compressor and its start relay/overload assembly (usually a small plastic module clipped to the compressor terminals).
  • Inspect start device: Remove the start relay/overload from the compressor. Shake it gently; if it rattles or smells burnt, it is likely defective.
  • Test continuity: With a multimeter, check continuity through the overload and PTC relay according to service specs. Open circuits indicate failure.
  • Replace start device if faulty: Order a "Midea compressor start relay and overload" kit for your model. Install on the compressor terminals exactly as the original, ensuring tight fit.
  • Check wiring and board: Inspect wires from the board to the compressor for burns or loose connections. If wiring and start device are good but E5 persists, the compressor itself or the main PCB may be defective.
  • Technician recommended: Diagnosing a locked compressor or replacing it requires specialized tools and refrigerant handling certification. Contact a professional if E5 remains after start device replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Start Relay and Overload Protector
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements