P3
Midea
Low Temperature Protection / Anti-Freeze Mode
Dehumidifier shows P3 and does not start compressor; fan may run.
Advertisements
Possible Causes
Room temperature below operating range, Faulty ambient temperature sensor reading too low, Unit placed near cold draft or on cold floor, Control board misinterpreting temperature
How to Fix / Troubleshooting
Note: P3 often indicates the unit is protecting itself from operating in too cold an environment.
- Check room temperature: Use a thermometer to verify the room is above the minimum operating temperature (typically 41°F / 5°C). If not, move the unit to a warmer location.
- Avoid cold drafts: Do not place the dehumidifier directly on a cold concrete floor or near open windows in winter. Elevate it slightly and keep away from cold walls.
- Reset: Unplug the unit for 5 minutes, then plug back in and test in a warmer area.
- If P3 persists in a warm room: The ambient temperature sensor may be faulty or mispositioned. See the E1 entry for sensor testing and replacement steps.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Ambient Temperature Sensor (NTC)
Check Price on Amazon