E5
Mitsubishi Electric
Communication Error Between Display PCB and Main PCB
Dehumidifier shows E5 and will not start; sometimes occurs after a power surge.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose display board connector, damaged communication harness, oxidized connector pins, failed display PCB, failed main control PCB
How to Fix / Troubleshooting
Safety: Unplug the unit before opening the control panel.
Steps:
- Check for simple reset: Unplug for 10 minutes, then reconnect. If E5 persists, proceed.
- Access control panel: Remove screws securing the top/front control panel. Carefully lift it to expose the display PCB and wiring.
- Inspect connectors: Locate the multi‑pin connector between the display PCB and the main PCB. Reseat both ends several times to wipe oxidation from the pins.
- Check harness: Look for pinched or broken wires in the harness bundle. Repair or replace if damaged.
- Visual inspection of PCBs: Look for burn marks, cracked solder joints at the connector, or corrosion. If present, the affected PCB should be replaced.
- Board substitution: If available, replace the display PCB first (usually easier and cheaper). If E5 remains, replace the main control PCB.
Warning: Do not attempt to repair PCB tracks or components unless you are qualified; incorrect repair can create a fire hazard.
Advertisements
Repair Difficulty
Hard
4/5