H1
Mitsubishi Electric Humidifier Water Supply / Tank Empty Detection

Humidifier function error H1; unit cannot raise humidity.

Advertisements

Possible Causes

Empty humidifier tank, stuck humidifier float, faulty humidifier level sensor, blocked water inlet to humidifier tray

How to Fix / Troubleshooting

Safety: Turn off and unplug the unit before handling water tanks.

Steps:

  • Check water level: Remove the humidifier tank and fill it to the indicated level with clean water. Reinstall firmly.
  • Inspect float: Ensure the float inside the humidifier tank or tray moves freely. Clean any scale or slime.
  • Check for leaks: Verify that water flows from the tank into the humidifier tray when installed. If not, the tank valve or seal may be stuck.
  • Sensor check: Locate the humidifier level sensor (float switch or electrodes) in the tray. Clean mineral deposits from the electrodes or float.
  • Replace: If the level sensor does not change state when water level changes, replace the humidifier level sensor assembly.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Humidifier Level Sensor / Float
Check Price on Amazon

We may earn a commission from links on this page.