H2
Mitsubishi Electric
Humidifier Element / Evaporative Filter Fault
Humidifier error H2; fan runs but no mist or moisture output.
Advertisements
Possible Causes
Clogged humidifier filter, failed humidifier fan, blocked water feed to filter, scale buildup on evaporative element
How to Fix / Troubleshooting
Safety: Unplug the unit. Water and electricity are present; avoid splashing near electrical parts.
Steps:
- Access humidifier section: Remove the front panel and pull out the humidifier cassette or filter frame.
- Inspect filter: Check the evaporative filter for heavy scale, discoloration, or mold. Replace if heavily contaminated.
- Clean tray: Rinse the humidifier tray and water channels to remove deposits that may block water flow.
- Check humidifier fan: Confirm that the small fan dedicated to the humidifier section (if present) runs when humidification is selected. If not, test and replace the humidifier fan motor.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Humidifier Evaporative Filter
Check Price on Amazon
We may earn a commission from links on this page.