Possible Causes
Worn or damaged keypad membrane, Moisture ingress into control panel, Loose ribbon cable to main PCB, Faulty display/control PCB
How to Fix / Troubleshooting
Steps:
- Power reset: Unplug the unit for 5 minutes and plug back in to rule out a temporary logic issue.
- Dry panel: If the panel is damp, allow it to dry completely. Do not spray cleaners directly onto the control panel.
- Check cable: Open the top/front cover and ensure the ribbon cable from the keypad to the main PCB is firmly connected.
- Panel replacement: If specific buttons never work or trigger wrong functions, replace the display/control PCB assembly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Control Panel Keypad / Display PCB
Check Price on Amazon