Olimpia Splendid Compressor Start Failure

Dehumidifier powers on but compressor never starts; only fan runs continuously.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor start relay, Open thermal overload protector, Faulty compressor windings, Defective main PCB relay or triac

How to Fix / Troubleshooting

Safety: Unplug the unit. Compressor circuits carry mains voltage.

Steps:

  • Confirm settings: Set humidity to a low value and ensure the room humidity is above the setpoint. Some units delay compressor start by a few minutes; wait at least 3–5 minutes.
  • Listen for clicks: When the compressor should start, listen for a relay click. No click may indicate a PCB issue.
  • Inspect compressor wiring: With covers removed, check that all wires to the compressor, overload protector, and start relay are secure.
  • Check overload and relay (advanced): Test continuity of the overload protector and start relay. Replace if open or burnt.
  • Compressor test: Measure compressor winding resistances if you are trained to do so. Shorted or open windings mean the compressor must be replaced by a refrigeration technician.
  • PCB replacement: If the compressor and start components are good, the main PCB may not be sending power to the compressor and will need replacement.