Olimpia Splendid
Loss of Refrigerant Charge / Weak Cooling Circuit
Dehumidifier runs but does not collect water; humidity in the room remains high.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Refrigerant leak in evaporator or condenser, Blocked capillary tube, Failing compressor, Severely dirty coils reducing heat exchange
How to Fix / Troubleshooting
Safety: Do not attempt to open the sealed refrigeration system yourself.
Steps:
- Check basic operation: Ensure the unit is set to a low humidity (e.g., 40%) and that the compressor actually runs (you should hear a deeper humming sound and feel warm air from the exhaust).
- Clean filters and coils: Remove and wash the air filter. Vacuum dust from the evaporator and condenser coils.
- Check room conditions: Dehumidifiers are less effective at low temperatures. Ensure the room is within the specified operating range.
- Inspect for icing: If the evaporator ices up quickly, there may be a refrigerant or airflow issue.
- Professional service: If the compressor runs but the evaporator does not get uniformly cold and no water is collected after several hours, the unit likely has a refrigerant problem or weak compressor. Contact an authorized Olimpia Splendid service center for leak detection and repair or compressor replacement.
Advertisements
Repair Difficulty
Professional Required
5/5
Advertisements