P3
Olimpia Splendid Low Ambient Temperature Protection

Dehumidifier shows P3 and stops compressor operation.

Advertisements

Possible Causes

Room temperature below minimum operating range, Faulty ambient temperature sensor reading too low, Unit placed on cold floor or near cold draft

How to Fix / Troubleshooting

Steps:

  • Verify room temperature: Use a separate thermometer to confirm the room is above the minimum temperature specified in the manual (often 5–7°C). If not, move the unit to a warmer area.
  • Relocate the unit: Avoid placing the dehumidifier directly on a very cold floor or next to an open window in winter, as this can cause the sensor to read too low.
  • Sensor check: If the room is warm but P3 persists, inspect and test the ambient NTC sensor as described for E1.
  • Board issue: If the sensor is good, the main PCB may be misreading temperature and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ambient NTC Temperature Sensor
Check Price on Amazon