P3
Olimpia Splendid
Low Ambient Temperature Protection
Dehumidifier shows P3 and stops compressor operation.
Advertisements
Possible Causes
Room temperature below minimum operating range, Faulty ambient temperature sensor reading too low, Unit placed on cold floor or near cold draft
How to Fix / Troubleshooting
Steps:
- Verify room temperature: Use a separate thermometer to confirm the room is above the minimum temperature specified in the manual (often 5–7°C). If not, move the unit to a warmer area.
- Relocate the unit: Avoid placing the dehumidifier directly on a very cold floor or next to an open window in winter, as this can cause the sensor to read too low.
- Sensor check: If the room is warm but P3 persists, inspect and test the ambient NTC sensor as described for E1.
- Board issue: If the sensor is good, the main PCB may be misreading temperature and require replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Ambient NTC Temperature Sensor
Check Price on Amazon