Olimpia Splendid
Humidifier Output Failure
Humidifier function (on combo unit) runs but no visible mist or humidity increase.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Empty or improperly seated water tank, Clogged ultrasonic transducer or wick filter, Faulty humidifier pump (if equipped), Failed humidifier control circuit
How to Fix / Troubleshooting
Steps:
- Check water supply: Ensure the humidifier tank is full and correctly seated. Some Olimpia Splendid combo units will not run the humidifier if the tank is misaligned.
- Clean components: If ultrasonic, gently clean the transducer disc with a cotton swab and white vinegar to remove scale. If wick-based, inspect and replace the wick filter if heavily scaled or discolored.
- Check for airlocks: On pumped systems, ensure there are no kinks in the water line and that the pump can draw water from the tank.
- Test in a small room: Run the unit in a small, closed room and monitor humidity with a separate hygrometer. If there is still no increase, the humidifier module or control board may be faulty and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Humidifier Module / Ultrasonic Transducer
Check Price on Amazon