Orbegozo Fan Not Running

Dehumidifier fan does not run, but compressor may start and overheat

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed fan motor, Seized fan bearings, Faulty fan capacitor (if separate), Loose wiring to fan

How to Fix / Troubleshooting

Safety: Unplug immediately if the compressor runs without the fan; this can cause overheating.

Steps:

  • Check for obstructions: Ensure nothing is blocking the fan blades.
  • Spin test: Try to spin the fan by hand. If stiff, the motor is likely seized and must be replaced.
  • Inspect wiring: Open the rear panel and check the fan motor connector and wires.
  • Replace fan motor: Install a new Orbegozo-compatible fan motor if the old one is seized or electrically open.
  • Capacitor check: If the motor uses an external capacitor, test and replace it if out of spec.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Fan Motor Assembly
Check Price on Amazon

We may earn a commission from links on this page.