Orbegozo Compressor Not Starting

Dehumidifier powers on but compressor never starts, only fan runs continuously

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty compressor start relay/PTC, Defective run capacitor, Open thermal protector on compressor, Main PCB not sending start signal

How to Fix / Troubleshooting

Safety: Unplug the unit. High voltage and stored energy in capacitors can be dangerous.

Steps:

  • Check operating mode: Ensure the humidity setpoint is below current room humidity and that the unit is not in fan-only mode.
  • Listen for compressor: After turning on, listen for a low humming sound. No sound may indicate no power to compressor.
  • Access compressor area: Remove rear/side panel to expose compressor, PTC/relay, and capacitor.
  • Inspect start components: Look for burnt or cracked PTC, bulged capacitor, or loose wires.
  • Replace suspect parts: If the capacitor is swollen or tests out of spec, or the PTC is cracked, replace with Orbegozo-specified components.
  • PCB diagnosis: If start components are good and compressor windings test OK, the main PCB may not be energizing the compressor relay and may need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Compressor Run Capacitor
Check Price on Amazon