E3
Orbegozo Humidity Sensor (RH Sensor) Failure

Dehumidifier shows E3 and compressor does not start

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed digital humidity sensor module, Loose or oxidized connector to main PCB, Broken sensor cable, Faulty main control board ADC circuit

How to Fix / Troubleshooting

Safety: Unplug the unit before inspection.

Procedure:

  • Reset attempt: Disconnect power for 10 minutes, then reconnect and check if E3 clears.
  • Locate humidity sensor: On Orbegozo dehumidifiers, the RH sensor is usually near the air intake grille or behind the front panel, often a small plastic module with vents.
  • Inspect sensor and wiring: Check for dust buildup, moisture, or corrosion. Ensure the connector is fully seated on the main PCB.
  • Clean sensor area: Use dry compressed air or a soft brush to remove dust. Do not spray liquids directly on the sensor.
  • Check cable continuity: If you have a multimeter, verify that each wire from the sensor to the PCB has continuity.
  • Replace humidity sensor module: If E3 persists and wiring is intact, install a new Orbegozo-compatible humidity sensor module for your model.
  • PCB diagnosis: If a new sensor does not resolve E3, the main control board may be defective and should be replaced by a qualified technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Humidity Sensor Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements