H2
Orbegozo Ultrasonic Transducer (Nebulizer) Fault

Humidifier shows H2 and does not produce mist

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ultrasonic ceramic disc, Mineral scaling on transducer, Damaged transducer wiring, Faulty driver circuit on PCB

How to Fix / Troubleshooting

Safety: Unplug the humidifier and empty the tank before working on the base.

Steps:

  • Descale the transducer: In the water basin, locate the round metal/ceramic disc. Gently clean mineral deposits using a cotton swab dipped in white vinegar, then wipe with clean water. Do not scratch the surface.
  • Check water level: Ensure the basin has sufficient water; some models protect the transducer when water is too low.
  • Inspect wiring: Open the base (if screws are provided) and check the transducer wires and connector to the PCB.
  • Replace transducer module: If H2 persists and the disc shows cracks or heavy pitting, replace the ultrasonic transducer module with an Orbegozo-compatible part.
  • PCB driver fault: If a new transducer does not work, the high-frequency driver circuit on the PCB may be defective and require board replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ultrasonic Transducer Module
Check Price on Amazon

We may earn a commission from links on this page.