Possible Causes

Empty or improperly seated water tank, Failed ultrasonic transducer, Blocked mist outlet, Faulty fan in humidifier

How to Fix / Troubleshooting

Safety: Unplug the humidifier and remove the tank.

Steps:

  • Check water level and seating: Fill the tank and ensure it is correctly positioned so the valve opens.
  • Inspect mist outlet: Remove any covers and check for blockages or mineral buildup. Clean with a soft brush.
  • Listen for transducer: When powered, you should hear a faint buzzing and see ripples in the water. If not, the transducer or driver may be faulty.
  • Clean transducer: Descale gently with vinegar and water as per manual.
  • Replace transducer or fan: If cleaning does not restore mist and the fan is not blowing, replace the ultrasonic transducer module or fan motor as needed.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ultrasonic Transducer Module