H19
Panasonic Indoor Fan Motor Position / Feedback Error

Unit stops and displays H19; fan may run but no dehumidification.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed fan motor hall sensor, Incorrect fan speed feedback to main PCB, Loose or corroded fan motor connector, Defective main control PCB fan driver

How to Fix / Troubleshooting

Safety first: Disconnect power before servicing.

  • Check fan operation: With the unit assembled, start it and observe fan behavior. Erratic speed, pulsing, or no start followed by H19 points to a motor or driver issue.
  • Inspect connector: Unplug the unit, remove the cover, and locate the multi‑wire connector from the fan motor to the main PCB. Reseat and inspect for bent pins.
  • Check for moisture damage: Look for signs of condensation or water ingress around the fan motor and connector. Dry thoroughly and correct any drainage issues.
  • Replace fan motor: If the motor does not start reliably or shows visible damage, replace with a Panasonic‑compatible DC fan motor assembly.
  • If problem persists: The main PCB’s fan driver circuit may be faulty and require board replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Indoor Fan Motor
Check Price on Amazon