Panasonic Excessive Condensate Production / High Load or Sensor Error

Water tank fills very quickly or overflows; humidity seems normal.

Advertisements

Possible Causes

Extremely high room humidity (e.g., water intrusion), Faulty humidity sensor reading too high, Continuous mode enabled, Poor room sealing causing constant moisture ingress

How to Fix / Troubleshooting

Safety first: Unplug before inspecting for water damage.

  • Check mode: Ensure the unit is not set to continuous mode if you want it to cycle off.
  • Verify humidity: Use a separate hygrometer to confirm actual humidity. If normal but the unit runs nonstop, suspect a sensor issue.
  • Inspect room: Look for water leaks, unvented dryers, or open windows that introduce moisture. Correct these issues.
  • Install continuous drain: If high humidity is expected (basements, laundry rooms), connect a drain hose to avoid tank overflow.
  • Replace humidity sensor: If readings are inaccurate and cause over‑dehumidification, replace the sensor module.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Humidity Sensor Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements